Multi Core Flexible Copper Conductor PVC Insulated PVC Sheathed Cable
Flexible Copper Conductor PVC Insulated PVC outer sheath cable
- Main target market:
- Minimum order quantity :
Exhibit parameters
- Exhibit code:SN009739
- Size of exhibits(mm):0.5-300
- Model of exhibits:H07VV-F;H05VV-F
- Materials of exhibits:
- Color of exhibits:Black
- Place of delivery:China-SHAN DONG -DE ZHOU
- Raw material production place:China-SHAN DONG -DE ZHOU
- Features of exhibits:

Details of exhibits
H05VV-F 3core 1.5mm2 Flexible Cable
H05VV-F Flexible Cables
|
|
Application:
H05VV-F Flexible cable
-These cables are suited for medium mechanical stress in damp and wet environments such as refrigerators, washing machines,
spin dryers and other appliances, as long as it meets applicable equipment specifications.
-These cables are also suited for cooking and heating apparatus, provided that the cable does not come into direct contact
with the hot parts of the apparatus or with any other heat source.
-Further applications of this cable include: Fixed installation in furniture, partition walls, decorative covering, and in the hollow
spaces of prefabricated building parts. They are not suitable for outdoor use, industrial (except clothing manufacture) or
farming applications.
Cable structure:
-Stranded bare copper conductor according to DIN VDE 0295 and IEC 60228 cl. 5 and HD 383
-Special PVC core insulation, cores stranded in layers with optimal lay-lenght
-Color coded cores according to DIN VDE 0293, from 7 cores and more black with white numbering
Two cores: blue/brown
Three cores: Yellow & Green/Blue/Brown
Four cores: Yellow & Green/Brown/Black/Grey
Five cores: Yellow & Green/Blue/Brown/Black/Gre
-Black or white PVC outer jacket according to DIN VDE 0207 part 5
-PVC self-extinguishing and flame retardant, according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1
Technical characteristics:
-PVC control cables according to DIN VDE 0281 part 5 and IEC60227-5, HD 21.5 S3
-Temperature range: flexing from -5 °C to +70 °C , fixed from -40 °C to +70 °C
-Nominal voltage Uo/U 300/500 V
-Test voltage a.c. 2000 V-Max. permissible operating voltage in three-phase and single-phase
a.c. system Uo/U 330/550 V
in direct current system Uo/U 495/825 V
-Minimum bending radius approx. 7,5 x cable diameter
H05VV-F Technical data:
Cores x Cross section area | Insulation thickness | Sheath thickness | External diameter | Conductor resistance at 20 °C | resistance of insulation at 70 °C |
nominal | nominal | min-max. | max. | min. | |
mm² | mm | mm | mm | Ω/km | MΩkm |
2X0.75 | 0.6 | 0.8 | 5.7-7.2 (3.7X6.0-4.5 X7.2) | 26 | 0.011 |
2X1 | 0.6 | 0.8 | 5.9-7.5 (3.9X6.2-4.7 X7.5) | 19.5 | 0.010 |
2X1.5 | 0.7 | 0.8 | 6.8-8.6 | 13.3 | 0.010 |
2X2.5 | 0.8 | 1.0 | 8.4-10.6 | 1.98 | 0.009 |
2X4 | 0.8 | 1.1 | 9.7-12.1 | 4.95 | 0.007 |
3X0.75 | 0.6 | 0.8 | 6.0-7.6 | 26 | 0.011 |
3X1 | 0.6 | 0.8 | 6.3-8.0 | 19.5 | 0.010 |
3X1.5 | 0.7 | 0.9 | 7.4-9.4 | 13.3 | 0.010 |
3X2.5 | 0.8 | 1.1 | 9.2-11.4 | 1.98 | 0.009 |
3X4 | 0.8 | 1.2 | 10.5-13.1 | 4.95 | 0.007 |
4X0.75 | 0.6 | 0.8 | 6.6-8.3 | 26 | 0.011 |
4X1 | 0.6 | 0.8 | 7.1-9.0 | 19.5 | 0.010 |
4X1.5 | 0.7 | 1.0 | 8.4-10.5 | 13.3 | 0.010 |
4X2.5 | 0.8 | 1.1 | 10.1-12.5 | 1.98 | 0.009 |